![]() ![]() * A flow meter (or flow sensor) is an instrument used to measure linear, nonlinear, mass or volumetric flow rate of a liquid or a gas. The device transmits a trip signal through to another device in the system, called a pump. ![]() All Rights Reserved.* The flow switch is designed to monitor the flow of air, liquid or steam. All meters come with power supply, cables, tube end connectors, inlet filter, and FLO-Sight TM companion PC softwareĬopyright © 2024 TSI.10 Point NIST-traceable Calibration Certificate included.Display four measurement parameters simultaneously.Also measures differential pressure, volume (with triggers), temperature, absolute pressure, and totalizer measurements.Wide dynamic operating range (1000:1 turndown ratio).Low pressure drop minimizes back pressure.4 millisecond bi-directional flow response.Temperature and pressure compensated mass flow rate.View all our materials and resources for the 5000 Series Flow Meters Looking to calibrate your TSI 5210-2 Flow Meter? TSI now offers worldwide service! To find out about our service, calibration, and repair options, visit our Flow Service page. *All 5200 Series flow meters come with 3/8 inch end adapters and end caps attached.* Calibration and Service 3/8 inch and 1/4 inch tubing (4 inch pieces).USB-C to USB-A power/communications cable.The low pressure drop of TSI flow meters minimizes flow circuit back pressure and its impact on the system. Fast sensor response ensures accuracy in fluctuating flows and is ideal for closed-loop control systems and integrated volume measurements. ![]() The TSI mass flow sensor design is optimized for applications where high accuracy, fast response, and low pressure drop are performance musts. Proven performanceĥ000 Series Flow Meters utilize a proprietary platinum film sensor with proven performance that’s been relied upon for more than 35 years. It is also ideal for the combined delivery oxygen concentrator option, which offers both a pulse dose and continuous flow option, because it measures pulse doses in varying sizes/frequencies, measures and delivers flow rate and volume of oxygen in mL, L, or ft 3, and logs raw measurement data. To learn more about this application, visit our Oxygen Concentrator Testing page. Model 5210-2 low flow meter is ideal for pulse dose oxygen concentrator (PD O 2 concentrator) testing because it measures the pulse volume and low flow flow rate for air/O 2 mix and displays the data right on the flow meter without having to connect it to a computer. Whether measuring gas flows in a laboratory, manufacturing, or service setting, the 5000 Series Flow Meter can adapt to fit your unique application. The 5000 Series Flow Meter also incorporates configurable tube end adapters, touchscreen control, and multiple mounting options. TSI Flow Meters are lightweight, compact, and can measure across a wide dynamic operating range. Connect and operate the gas flow meter through your PC with FLO-Sight software to take advantage of advanced data display and device settings options. Quickly and easily configure measurements and device settings directly from the flow meter. View up to four readings simultaneously from the color touchscreen display of this Air and O 2 flow meter. Precise volume measurements and the ability to log measurement data make this model ideal for testing oxygen concentrators (O 2 concentrators). 5210 models also include a built-in data logger that can save synchronized measurement data directly to the flow meter. In addition to the totalizer, these volumetric flow meters can make precise volume measurements through the use of flow or pressure triggers. Flow Multi-Meter advanced functionalityĥ210 mass flow meters include a differential pressure sensor that enables users to measure the pressure differential of flows at the flow meter or at any point in the line. All 5200 Series inline flow meter models come with a standard accessory kit (see full list below). In addition to temperature and absolute pressure measurements, a built-in totalizer measurement enables users to make volume measurements as a running total. Integrated temperature and pressure sensors compensate flow measurements to provide mass flow readings independent of temperature or pressure. The TSI Mass Flow Multi-Meter 5210-2 provides a bi-directional flow rate measurement with 2% of reading accuracy across a wide flow range. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |